Cloudbreak™ Sequencing Kits
Cloudbreak sequencing kits provide the sequencing reagents and flow cell for a run on the Element AVITI™ System with multiple read lengths and output options to suit any application. Leveraging avidite base chemistry (ABC), Cloudbreak kits deliver simplified workflows and Q50 data quality (with UltraQ™) with low costs and rapid turnaround times.
Powerfully flexible
Cloudbreak sequencing kits enable a range of applications and scale for experiments of any size. Comprehensive sequencing kits run any read length from 2 x 75 to 2 x 300 with low-, medium-, and high-output kits allowing you to dial in a precise number of reads while maintaining affordability.
If your application requires low output, you can run your samples immediately with 2 x 75 low output kits—no need to wait to batch them. Leverage faster turnaround and the lowest run cost to get to your data faster.
Simplified workflows and seamless compatibility
Cloudbreak Freestyle™ kits simplify your AVITI sequencing workflow like never before. By enabling linear library loading and circularization onboard the AVITI System, Cloudbreak Freestyle eliminates the library conversion step, saving valuable preparation time and ensuring seamless integration with your existing library prep workflows.
Setting a new standard: Q50+ data quality
Cloudbreak UltraQ sets a new standard for sequencing accuracy, pushing the potential of the AVITI system even higher. With the highest accuracy specification on the market today, UltraQ delivers 70% of reads at Q50 or above and 90% of reads at Q40 or above. By using multiple strategies to reduce the most abundant error types arising from library prep and sequencing, it provides the firmest possible foundation for the development of highly sensitive assays.
Included in Each Kit
- Flow cell encased in a plastic cartridge for safe handling.
- Cartridge that conveniently packages sequencing reagents.
- Buffer bottle that supplements the cartridge with a large buffer volume.
- Library loading buffer to dilute libraries to the target loading concentration.
- Adept™ primer set that provides primers compatible with Adept libraries (original Cloudbreak kits only).
Catalog Numbers
Swipe left in the table to show more columns.
Name | Catalog # | Number of Cycles | Number of Reads* | Output (Gb) |
Cloudbreak UltraQ (CB UltraQ) Kits | ||||
AVITI 2x150 Sequencing Kit CB UltraQ | 860-00018 | 323 | 800 million | 240 |
Cloudbreak Freestyle (FS) Kits | ||||
AVITI 2x75 Sequencing Kit Cloudbreak FS Low Output | 860-00034 | 184 | 100 million | 15 |
AVITI 2x75 Sequencing Kit Cloudbreak FS Medium Output | 860-00014 | 184 | 500 million | 75 |
AVITI 2x75 Sequencing Kit Cloudbreak FS High Output | 860-00015 | 184 | 1 billion | 150 |
AVITI 2x150 Sequencing Kit Cloudbreak FS Low Output | 860-00011 | 334 | 250 million | 75 |
AVITI 2x150 Sequencing Kit Cloudbreak FS Medium Output | 860-00012 | 334 | 500 million | 150 |
AVITI 2x150 Sequencing Kit Cloudbreak FS High Output | 860-00013 | 334 | 1 billion | 300 |
AVITI 2x300 Sequencing Kit Cloudbreak FS Medium Output | 860-00016 | 634 | 100 million | 60 |
AVITI 2x300 Sequencing Kit Cloudbreak FS High Output | 860-00017 | 634 | 300 million | 180 |
Cloudbreak Kits | ||||
AVITI 2x75 Sequencing Kit Cloudbreak Medium Output | 860-00007 | 184 | 500 million | 75 |
AVITI 2x75 Sequencing Kit Cloudbreak High Output | 860-00004 | 184 | 1 billion | 150 |
AVITI 2x150 Sequencing Kit Cloudbreak Low Output | 860-00005 | 334 | 250 million | 75 |
AVITI 2x150 Sequencing Kit Cloudbreak Medium Output | 860-00006 | 334 | 500 million | 150 |
AVITI 2x150 Sequencing Kit Cloudbreak High Output | 860-00003 | 334 | 1 billion | 300 |
AVITI 2x300 Sequencing Kit Cloudbreak Medium Output | 860-00009 | 634 | 100 million | 60 |
AVITI 2x300 Sequencing Kit Cloudbreak High Output | 860-00008 | 634 | 300 million | 180 |
Accessory Kits | ||||
PhiX Control Library, Adept | 830-00004 | |||
Cloudbreak PhiX Control Library, Elevate | 830-00017 | |||
Cloudbreak FS PhiX Control, 3rd Party | 830-00023 |
*Performance metrics, including read counts, are based on sequencing Element-prepared libraries. Actual results might differ based on factors such as library type and preparation.